11. Troubleshooting guide
Fault Possible causes Remedy
Motor does not start a) No power at the plug
b) Cable defective
c) Switch/plug block defective
d) Motor terminals or capacitor
disconnected
e) excessive working depth
a) Check the power cable and fuse
b) Check
c) By customer service workshop
d) By customer service workshop
e) Reduce working depth
Motor performance
drops
a) Soil too hard
b) Blades badly worn
a) Correct working depth
b) Replace hoe blades
Important note!
For protection, the motor is equipped with a thermal switch which cuts out when the motor is
overloaded and switches on again automatically after a short cooling period.